This is a sample of the revenue diagnostic's report, so you can see what it checks and what you receive.
| Battery | Example Battery (fictional), 50 MW / 100 MWh, Great Britain |
| Owner | Example Storage Ltd (fictional) |
| Optimiser | Example Optimiser Ltd (fictional) |
| Agreement | Revenue share. The owner receives 85% of net eligible revenue each month. The optimiser keeps 15% as its fee and bears its own platform costs (Schedule 2). Settlement adjustments for earlier months flow into the statement following the settlement run (clause 7.3). |
| Delivery month | March 2026 |
| Evidence checked | The agreement and its amendment; the April statement (March, original) and the May to August statements; the April self-billing invoice; the owner's bank statement; Elexon's metered volumes and settlement amounts for the battery's Balancing Mechanism unit in each settlement run to date; the auction results of NESO (the National Energy System Operator) by unit; the owner's operator log |
| Not available | The optimiser's exchange trades and achieved prices; the battery's telemetry |
What the owner was paid for March
| Line on the April statement | Amount |
|---|---|
| Wholesale trading revenue | £182,400.00 |
| Balancing Mechanism | £48,200.00 |
| Dynamic Containment | £21,600.00 |
| Capacity Market | £9,750.00 |
| Eligible revenue | £261,950.00 |
| Charging costs (1,100 MWh) | −£96,305.00 |
| Imbalance charges | −£3,150.00 |
| Net eligible revenue | £162,495.00 |
| Owner's share (85%) | £138,120.75 |
| Platform fee | −£1,200.00 |
| Paid to the owner on 28/04/2026 | £136,920.75 |
Findings
| Finding | Direction | Amount | Evidence | Status | |
|---|---|---|---|---|---|
| F1 | Elexon's first reconciliation run, R1, came out for March's days between late April and late May, about seven weeks after each day. It gives the battery £54,200.00 for March in the Balancing Mechanism, £6,000.00 more than the £48,200.00 on the April statement. No statement from June to August carries an adjustment for March. Clause 7.3 says it should have followed in the next statement. | Owner underpaid | £5,100.00 (85% of £6,000.00) | Elexon settlement amounts, Settlement Final (SF) and R1; June to August statements | Not reconciled from the available evidence |
| F2 | A platform fee of £1,200.00 was deducted from the owner's payment. Schedule 2 puts platform costs on the optimiser. | Owner underpaid | £1,200.00 | Agreement, Schedule 2; April statement | Not reconciled from the available evidence |
| F3 | NESO's results show the battery holding Dynamic Regulation on four days in March. The statement has no Dynamic Regulation line. The award's value at the clearing prices is £1,640.00 before any performance deductions, which public data does not show. | Possibly underpaid | up to £1,394.00 (85% of £1,640.00) | NESO auction results by unit; April statement | Possible; needs the optimiser's NESO settlement statement |
| F4 | The meters show 1,120 MWh of import in March; the statement deducts charging costs for 1,100 MWh at £87.55/MWh. The 20 MWh missing from the deduction is £1,751.00. | Owner overpaid | £1,488.35 (85% of £1,751.00) | Elexon metered volumes; April statement | Not reconciled from the available evidence |
Matched: the payment formula is the one in force for March (the amendment of 01/01/2026 was applied); the Dynamic Containment line agrees with NESO's results at the clearing prices; the Capacity Market line agrees with the credit note; no availability adjustment was made, and the operator log records no outage; the bank receipt matches the self-billing invoice to the penny.
Could not be checked: whether the wholesale revenue of £182,400.00 is what the optimiser achieved, since its trades were not provided (the metered export valued at the day-ahead price comes to £176,900.00, a plausible difference that the trades would settle); the imbalance charge of £3,150.00, which depends on the optimiser's contracted position.
Summary for March
| Amount | |
|---|---|
| Not reconciled, owner underpaid (F1, F2) | £6,300.00 |
| Possible, owner underpaid (F3) | up to £1,394.00 |
| Not reconciled, owner overpaid (F4) | £1,488.35 |
Questions to put to the optimiser
- F1: "Elexon's R1 run for March gives our unit £6,000.00 more in the Balancing Mechanism than your April statement. Which statement carries that adjustment under clause 7.3?"
- F2: "Under Schedule 2, platform costs are yours. Why was £1,200.00 deducted from our March payment?"
- F3: "NESO's results show Dynamic Regulation held on four days in March. Please send the NESO settlement statement for those days and show where the revenue appears."
- F4: "Our meters show 1,120 MWh of import in March, and the statement deducts 1,100 MWh. Which readings did you use?"
What a historical review would need
The same evidence for each month under review, from the start of the agreement or the last month already agreed with the optimiser; the agreement's full amendment history; and the optimiser's NESO settlement statements, which would settle findings like F3.
Illustrative and fictional throughout. A real diagnostic reports only what the client's own documents and the published records show, and says which findings rest on which evidence.