This is a sample of the revenue diagnostic's report, so you can see what it checks and what you receive.

Everything in this report is fictional. The battery, the owner, the optimiser, the agreement and every amount are invented to show what the diagnostic delivers. No real company's data is used.
Battery Example Battery (fictional), 50 MW / 100 MWh, Great Britain
Owner Example Storage Ltd (fictional)
Optimiser Example Optimiser Ltd (fictional)
Agreement Revenue share. The owner receives 85% of net eligible revenue each month. The optimiser keeps 15% as its fee and bears its own platform costs (Schedule 2). Settlement adjustments for earlier months flow into the statement following the settlement run (clause 7.3).
Delivery month March 2026
Evidence checked The agreement and its amendment; the April statement (March, original) and the May to August statements; the April self-billing invoice; the owner's bank statement; Elexon's metered volumes and settlement amounts for the battery's Balancing Mechanism unit in each settlement run to date; the auction results of NESO (the National Energy System Operator) by unit; the owner's operator log
Not available The optimiser's exchange trades and achieved prices; the battery's telemetry

What the owner was paid for March

Line on the April statement Amount
Wholesale trading revenue £182,400.00
Balancing Mechanism £48,200.00
Dynamic Containment £21,600.00
Capacity Market £9,750.00
Eligible revenue £261,950.00
Charging costs (1,100 MWh) −£96,305.00
Imbalance charges −£3,150.00
Net eligible revenue £162,495.00
Owner's share (85%) £138,120.75
Platform fee −£1,200.00
Paid to the owner on 28/04/2026 £136,920.75

Findings

Finding Direction Amount Evidence Status
F1 Elexon's first reconciliation run, R1, came out for March's days between late April and late May, about seven weeks after each day. It gives the battery £54,200.00 for March in the Balancing Mechanism, £6,000.00 more than the £48,200.00 on the April statement. No statement from June to August carries an adjustment for March. Clause 7.3 says it should have followed in the next statement. Owner underpaid £5,100.00 (85% of £6,000.00) Elexon settlement amounts, Settlement Final (SF) and R1; June to August statements Not reconciled from the available evidence
F2 A platform fee of £1,200.00 was deducted from the owner's payment. Schedule 2 puts platform costs on the optimiser. Owner underpaid £1,200.00 Agreement, Schedule 2; April statement Not reconciled from the available evidence
F3 NESO's results show the battery holding Dynamic Regulation on four days in March. The statement has no Dynamic Regulation line. The award's value at the clearing prices is £1,640.00 before any performance deductions, which public data does not show. Possibly underpaid up to £1,394.00 (85% of £1,640.00) NESO auction results by unit; April statement Possible; needs the optimiser's NESO settlement statement
F4 The meters show 1,120 MWh of import in March; the statement deducts charging costs for 1,100 MWh at £87.55/MWh. The 20 MWh missing from the deduction is £1,751.00. Owner overpaid £1,488.35 (85% of £1,751.00) Elexon metered volumes; April statement Not reconciled from the available evidence

Matched: the payment formula is the one in force for March (the amendment of 01/01/2026 was applied); the Dynamic Containment line agrees with NESO's results at the clearing prices; the Capacity Market line agrees with the credit note; no availability adjustment was made, and the operator log records no outage; the bank receipt matches the self-billing invoice to the penny.

Could not be checked: whether the wholesale revenue of £182,400.00 is what the optimiser achieved, since its trades were not provided (the metered export valued at the day-ahead price comes to £176,900.00, a plausible difference that the trades would settle); the imbalance charge of £3,150.00, which depends on the optimiser's contracted position.

Summary for March

Amount
Not reconciled, owner underpaid (F1, F2) £6,300.00
Possible, owner underpaid (F3) up to £1,394.00
Not reconciled, owner overpaid (F4) £1,488.35

Questions to put to the optimiser

  • F1: "Elexon's R1 run for March gives our unit £6,000.00 more in the Balancing Mechanism than your April statement. Which statement carries that adjustment under clause 7.3?"
  • F2: "Under Schedule 2, platform costs are yours. Why was £1,200.00 deducted from our March payment?"
  • F3: "NESO's results show Dynamic Regulation held on four days in March. Please send the NESO settlement statement for those days and show where the revenue appears."
  • F4: "Our meters show 1,120 MWh of import in March, and the statement deducts 1,100 MWh. Which readings did you use?"

What a historical review would need

The same evidence for each month under review, from the start of the agreement or the last month already agreed with the optimiser; the agreement's full amendment history; and the optimiser's NESO settlement statements, which would settle findings like F3.


Illustrative and fictional throughout. A real diagnostic reports only what the client's own documents and the published records show, and says which findings rest on which evidence.